
Minute Virus of Mice (MVM) ELISA Kit (Qualitative)
2026-05-13
Human Hantavirus (HV) ELISA Kit (Qualitative)
2026-05-14Hantavirus Cardiopulmonary Syndrome (HCPS) PCR Kit
Product Number: DTK587
Shipping and Storage
- Reagents should be kept away from light and sealed. Reagent components should be stored at -20 ± 5℃. The validity period of the reagent kit is 12 months.
- Please refer to the outer packaging box for the production date and expiration date.
- Curling with ice or foam box with blue ice seal (2-8℃) shall be used for transportation.
- Store in the dark at -20 ± 5℃ after opening; Freeze repeatedly no more than 7 times.
Component
| Component | 25T | 50T | Main components |
| PCR reaction solution | 475μL | 950μL | dNTPs, MgCl2, RNasin, PCR buffer, Probes, primers, etc |
| Eenzyme mixture | 25μL | 50μL | UNG enzyme, reverse transcriptase, Taq enzyme |
| Positive control | 0.2mL | 0.2mL | Plasmid containing Hantavirus Heart Lung Syndrome (HCPS) target gene and internal standard gene |
| Negative control | 0.2mL | 0.2mL | Buffer |
- The ingredients of products with different batch numbers cannot be mixed or exchanged.
- Required but not provided reagents: nucleic acid extraction or purification reagents.
Description
This reagent kit is designed for the conserved gene sequences of Hantavirus Cardiopulmonary Syndrome (HCPS) related viruses (including Andean Hantavirus). Specific primers and probes are designed, and fluorescence PCR technology is applied to qualitatively detect the nucleic acid of Hantavirus HCPS related viruses through changes in fluorescence signal.
The PCR detection system also includes specific primer probes for endogenous internal standard nucleic acid substances (human housekeeping genes), which monitor the entire process of sample collection, extraction, and amplification by checking whether the internal standard detection signal is normal, avoiding false negative results.
Application
This kit is used for qualitative detection of Hantavirus Cardiopulmonary Syndrome (HCPS) related viral nucleic acids and can specifically detect Hantavirus Cardiopulmonary Syndrome (HCPS) containing Andean Hantavirus.
The experimental results only provide reference for basic research and are not used as clinical diagnostic basis.
Applicable instruments
Suitable for multi-channel fluorescence quantitative PCR instruments such as SLAN-96P, Gentier 96R, AGS 4800, ABI7500, Roche LightCycler480/480 II, Bio Rad CFX96, ABI QuantStudio 5/6/7, QuantStudio Dx, etc.
Specimen collection
- Applicable sample types: various clinical specimens and pathogen isolates, etc.
- Sample preservation and transportation: The samples to be tested should be processed as soon as possible, and specimens that can be tested within 24 hours can be stored at 4 ℃; Specimens that cannot be detected within 24 hours can be stored at -70℃ or below for a long time (if there is no -70℃ storage condition, the test sample can be stored at -20±5℃ for 1 month). Repeated freeze-thaw cycles should not exceed 5 times. The samples shall be transported by means of curling bottle with ice or foam box with ice seal.

